????SOFT STARTER X FREQUENCY INVERTER, when to use ONE or THE OTHER

57,977 views

Engehall Eletricista Industrial

Published on May 3, 2022
About :

????Check out our ELECTRICAL COMMANDS course https://eletr.co/ce?utm_content=x9RGf... ...................................................................... ✅ Did you like this video? ✅ Subscribe to the channel ➽ https://eletr.co/industrial ✍️ Leave your comment ???? Share with friends ???? Follow our networks ➽ https://eletr.co/links ..................................................................... Hey my electrician friend!! Today we are going to learn a little about when to use a frequency inverter or a soft stater. ...................................................................................... When to use a soft starter or a frequency inverter? It is a very common question among electricians, deciding between a soft starter or a frequency inverter, so which electronic starter should I use? First, we need to understand how both Soft-Starters work. They are static starters designed to accelerate, decelerate and protect three-phase induction electric motors by controlling the voltage applied to the motor. The frequency inverter is used to control the motor speed, i.e., it is a device used in three-phase electric motors to drive, vary the frequency and voltage to control the rotation speed and power consumed. Basically, when the objective is to simply drive the motor, we use the soft starter. When the objective goes beyond starting, to be able to control the actions of the motor shaft end and/or automate the process, the frequency inverter should be used. What determines which component will be used is basically the type of function required and the function that the component offers. Soft starter • Low to medium starting torque applications • Light load applications • Low or no speed control during run mode • Reduced mechanical wear and tear and system damage • Power-up control • Power monitoring Variable frequency drives • Single-phase applications in some drives • Speed ​​control and operating system efficiencies at reduced speeds during run mode • High starting torque applications • Continuous feedback for critical position control • Holds rotor at zero speed • Reduced mechanical wear and tear and system damage Programmed starts Starting times up to 30 seconds are typical, but most soft starters have some capabilities in excess of 30 seconds, up to 999 seconds. Long starting times are not normal, and the thermal capabilities of the system, including the motor, must be considered. Acceleration times can be set to 3600 seconds. Long times are typically associated with high inertia loads, reducing the drive size required. Knowing how and when to use this type of component is very important, as is always being careful to apply the knowledge in the safest way possible, thus avoiding possible different electrical accidents. In conclusion, a frequency inverter can always replace a soft-starter, but the opposite is not possible. bibliographical references: Source: Therba FREQUENCY INVERTERS AND SOFT STARTER – MAIN DIFFERENCES (therba.com.br) #embaixadordecomandosengehall

Trend Videos
29:22
LCK
324,539 views   18 hours ago
28:38
242,207 views   17 hours ago
10:24
29:22
LCK
324,539 views   18 hours ago
28:38
242,207 views   17 hours ago
12:20
326,594 views   2 days ago
0:19
81,451 views   11 hours ago
12:20
326,594 views   2 days ago
28:38
242,207 views   17 hours ago
48:25
854,143 views   1 day ago
Google AdSense
336 x 280
Up Next
18:53
Erivaldo Grid Solar
1,530 views
1 day ago
1:08:03
WG ELETRIC CURSOS
112 views
10 days ago
30:12
Eduardo Aquino
15,530 views
1 year ago
17:16
E4 Energias Renováveis
8,025 views
2 years ago
20:00
WG ELETRIC CURSOS
58 views
2 weeks ago
20:36
Erivaldo Grid Solar
23,184 views
1 year ago
8:32
Energia Solar Fácil - Tarcisio Simone
13,438 views
1 year ago
15:19
Harb Mecatrónica
5,707 views
2 months ago
42:11
AutomatizandoPro
49,098 views
3 years ago
1:14:15
Victor Leiva
8,452 views
3 years ago
27:19
1:16:55
Elvatron S.A.
6,618 views
3 years ago
20:35
ElectriSistemaS
71,432 views
3 years ago
14:53
هندسة لف المواتير والمولدات Hany Tourky
10,038 views
8 months ago
16:24
EL TALLER DE LEZCANO
51,962 views
4 years ago
18:29
RENOVETEC
177,504 views
2 years ago
Google AdSense
336 x 280

fetery.com. Copyright 2024