???? If you DO NOT install the FRAME LIKE THIS, WATER WILL GET IN

69,733 views

Engehall Elétrica

Published on Mar 17, 2020
About :

⚡️ FREE CLASS: How to Do a Complete Electrical Installation from Scratch, Easily, Even if You Are Not a Professional Electrician: ➽ https://eletr.co/aula?utm_content=yt1... ------ ???? FAAALA ENGEHALL COMMUNITY ???? Join our community on WhatsApp to receive valuable tips and news in the electrical area, important information and much more. ???? ???? https://eletr.co/fala-eng?utm_content= ------ Did you like this video? ???? ✔️ Leave your comment and share with friends ✔️ Follow our networks ➽ https://eletr.co/links - - - - - - - - - - - - - - - - - - - - - - - - - - - - If you DO NOT install the PANEL LIKE THIS, WATER WILL GET IN You are fixing the frame to the wall. First, he marks the locations of the holes on the wall and then drills them with a 6-gauge concrete drill bit. We're going to make 4 holes here to fix the board according to the guide at the bottom of the board. We're using an S6 bushing with a tab, which we really like because the tab doesn't let it go into the hole and disappear there. Finally, we use a Phillips screw with a washer to give better support to the bottom of the board, which looks great. With the board assembled, we continue to make the infrastructure. Note that there's already a small box fixed to the wall. This will be responsible for powering one of the machines that will be right above it. Now we're drilling other points to place the electrical conduit for the board's power supply branch. Here, we're attaching all the neutral, phase and ground cables to the guide probe. This is when we use the most insulating tape, after all, we need to attach the cables well to the cable gland so they don't come loose inside the piping. With the cables attached to the guide, we start the distribution to power the machines. In this corridor, we'll have two machines carrying two different circuits. We need to be very careful in this part so as not to damage the insulation of the cables. After all, it is a galvanized structure that may have metal burrs that end up cutting the insulating layer, which can cause short circuits and current leaks. Now we are pulling the power cables and also the cables from one of the air conditioning circuits on the other side of the house. These cables are all together in the same duct. While one pulls the cables into the panel, the other guides them from the other point to help. The three 6mm power cables and three more 2.5mm cables for the air conditioning on the other side of the house run through this duct. It is time to organize the cables and assemble the panel. First, we separate all the ground and phase cables on the panel to place the track with the circuit breakers. Note that at the bottom of the panel we use these little caps. They are used to seal the holes we made to fix the panel to the wall. This prevents water from entering the panel. If you do not install the panel like this, there is a high risk of water getting in. Once all the cables are organized, it's time to put all the circuit breakers and busbars on the panel. This will be really easy because we already assembled everything in the studio, remember? Here the rail is ready and we just need to fit it and screw it in. The advantage is that the screws are on the sides of the rail, so it doesn't get in the way when fixing everything together. Look how beautiful these circuit breakers look assembled. Charlão did the honors of putting this picture together. I really liked his ideas, really cool. Time to cut the ends of the cables and crimp them. First, we always cut all the ends to make everything right, then we strip them to put the tubular terminals on. With the crimping pliers, I crimp the ends of the 2.5mm cables and put tubular terminals on them to tighten the circuit breaker better and give the panel a better finish. Then it's time to connect the grounding cables. The big advantage here is that we won't need to use tubular terminals, look how wonderful. The fact that we replaced the screw grounding busbar with spring connectors helped us a lot. We then strip the ends of all the green ground cables to connect them to our Wago busbar. Just open the lever, insert the cable and close the lever, it's that simple. Note that there is a jumper with a green cable connecting the two 5-way connectors. In this case, it is possible to connect up to 8 ground cables to the connectors, after all, there are 10 terminals for 6mm² cables.

Trend Videos
23:38
498,795 views   12 days ago
26:20
10:24
12:17
5:53
1,185,384 views   6 days ago
8:31
197,460 views   2 days ago
Google AdSense
336 x 280
Up Next
15:57
Nick Chernobaev
1,193,343 views
3 years ago
10:17
Мозгоправ
2,463,635 views
2 years ago
8:08
Мозгоправ
6,000,394 views
3 years ago
1:31:44
14:53
Марьпална
526,485 views
3 years ago
6:32
Мозгоправ
2,620,575 views
3 years ago
18:35
Немного Лучше
1,912,821 views
1 year ago
17:33
Scammers
1,560,866 views
3 years ago
7:46
Таблетка Саморазвития
823,028 views
4 years ago
12:24
11:31
KRAMARTY TV - Мэтт Д'Авелла на русском
1,700,227 views
2 years ago
7:04
Простые Мысли
1,807,262 views
2 years ago
22:25
Немного Лучше
2,442,312 views
2 years ago
19:01
Букич
2,188,148 views
3 years ago
14:24
M Generation
4,208,186 views
4 years ago
8:16
Таблетка Саморазвития
3,323,008 views
6 years ago
11:58
Немного Лучше
3,811,252 views
3 years ago
18:00
Юнат Кофе Tour
764 views
2 weeks ago
11:45
sertixse
66 views
1 day ago
22:36
Рай-блогера
134 views
9 days ago
11:42
Irella Lisitsyna // Ирелла Лисицына
18 views
6 days ago
17:42
Юнат Кофе Tour
549 views
6 days ago
12:17
8:57
Мари Беккар про креативность
16 views
12 days ago
0:35
Sasha Eridan
119 views
8 hours ago
12:58
Плешь со Смыслом
177 views
2 weeks ago
8:36
Литература покорила
205 views
4 days ago
3:48
33:11
Книжный_бордель
68 views
5 days ago
8:46
Саша Баранчеев
75 views
5 days ago
0:22
Sasha Eridan
421 views
2 weeks ago
Google AdSense
336 x 280

fetery.com. Copyright 2024