How to test the electronic expansion valve coil of the Daikin Ecoswing inverter air conditioner

1,498 views

GN Engenharia

Published on Nov 27, 2023
About :

Testing the electronic expansion valve coil of the Daikin Ecoswing R32 Smart inverter air conditioner. I POWERED IT WITH 12VDC, WITH THE POSITIVE IN THE GRAY AND THE NEGATIVE FOR EACH WIRE, ORANGE, RED, YELLOW AND BLACK. IT PRESENTED A CURRENT OF 240mA, but as the yellow one is short-circuited, it did not present any current. I tested it using an adjustable source from 0 to 30V with short-circuit protection. Schematic image in Proteus 8 Professional https://uploaddeimagens.com.br/imagen... Schematic of how to test taken from the service manual https://uploaddeimagens.com.br/imagen... Service manual https://www.4shared.com/s/f2zvxQPTqjq