9,913 views
https://podzemnayamoskva.ru/ — excursions to the fallout shelter. https://t.me/v_bunkere_ne_strashno — our telegram channel about the underground @podzemnayamoskva — main channel Today we will study another interesting exhibit of our underground museum! This time we decided to move away from the topic of communications, disassemble and restore a device that does not even have anything electrical. This is the SD-3 device for checking the breathing resistance of gas mask filters. Such devices are installed in shelters to make sure that the stored filters are in good condition. It is difficult to overestimate the importance of such a check, because a faulty filter can lead to the death of a person. In the video, we disassemble the SD-3, study its internal structure, repair and launch it! Now, after filming the video, the device is on display in good condition and can be seen and launched on excursions to our museum-shelter. As a bonus, visitors to the museum can check the filter of their gas mask :)